|
Providing superior
temperature
testing and
conditioning Chambers and Platforms
that are Sigma Quality is |
The powder coated stainless steel housing is easy to clean and always looks good. Waterproof high temperature foam around the platform perimeter keeps moisture out of the platform insulation during low temperature operations. A thermal shield over the exhaust protects users during extreme temperature operation.
Proprietary Sigma coolant metering valve(s) are quiet, exceptionally durable, and easy to service. A coolant filter protects the coolant control valves and vaporization channel from contamination. Removable bottom plate allows cleaning of cooling channel to renew efficiency after years of service, or the introduction of contaminated coolant.
All Sigma ATP thermal platforms include a fixed limit high temperature failsafe. Adjustable high & low limit precision failsafe is optional.
Convenient wiring terminal allows connection of optional second temperature probe for use with C5 controller. Standardized controller interface connector allows swapping or upgrading controllers with ease. Coolant valve(s) are housed inside to reduce noise and ice build up. Optional redundant safety valve also fits inside. All low voltage power supply and line voltage power switching components are inside platform chassis and designed for easy service.
2(liquid carbon dioxide) cooling. L-N
2provides control to
2is efficient to about –55°C, with temperatures of –65°C to –70°C achievable at lower efficiency. Expected pressure for L-N
2is approximately 90-100 psig (7.2-7.9 bar). Lower pressures typical of bulk L-N
2systems will result in slower cooling performance with greater possibility of temperature latency or oscillation. Expected L-CO2 pressure is approximately 870 psig (70 bar) for performance listed. Users using 300 psig (21.7 bar) refrigerated L-CO
2can expect cooling performance slower than listed rates.
If precision, speed, innovative design, and durable operation are of
interest to you then Sigma Quality is the Ultimate Value.
Why Sigma Platforms are Superior
How to Select
the Correct Size of Platform
Chambers vs Platforms
Cryogenic vs Mechanical Cooling
Platform (plate) Accessories
Controllers and failsafes
Drill Mask for Thermal Platforms
|
About Sigma Sigma Superiority
Tech Support
Documents and Downloads 2 Year Parts & Labor Warranty Employment Opportunities Request Literature/Brochures |
|
| Copyright © 1998-2008 Sigma Systems Corporation, El Cajon, CA, USA | ||